<mods xmlns="http://www.loc.gov/mods/v3" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-4.xsd">
    
    <titleInfo>
        <title>Hexagonal wavelet processing of digital mammography</title>
    </titleInfo>
    <name type="personal" ID="al418">
        <namePart type="family">Laine</namePart>
        <namePart type="given">Andrew F.</namePart>
        <role>
            <roleTerm type="text">author</roleTerm>
        </role>
        <affiliation>Columbia University. Biomedical Engineering</affiliation>
        <affiliation>Columbia University. Radiology</affiliation>
    </name>
    <name type="personal">
        <namePart type="family">Schuler</namePart>
        <namePart type="given">Sergio</namePart>
        <role>
            <roleTerm type="text">author</roleTerm>
        </role>
    </name>
    <name type="personal">
        <namePart type="family">Huda</namePart>
        <namePart type="given">Walter</namePart>
        <role>
            <roleTerm type="text">author</roleTerm>
        </role>
    </name>
    <name type="personal">
        <namePart type="family">Honeyman</namePart>
        <namePart type="given">Janice</namePart>
        <role>
            <roleTerm type="text">author</roleTerm>
        </role>
    </name>
    <name type="personal">
        <namePart type="family">Steinbach</namePart>
        <namePart type="given">Barbara</namePart>
        <role>
            <roleTerm type="text">author</roleTerm>
        </role>
    </name>
    <name type="corporate">
        <namePart>Columbia University. Biomedical Engineering</namePart>
        <role>
            <roleTerm type="text">originator</roleTerm>
        </role>
    </name>
    <typeOfResource>text</typeOfResource>
    <genre>Articles</genre>
    
    <originInfo>
        <dateIssued encoding="w3cdtf" keyDate="yes">1993</dateIssued>
    </originInfo>
    
    <language>
        <languageTerm type="text">English</languageTerm>
    </language>
    <abstract>This paper introduces a novel approach for accomplishing mammographic feature analysis through overcomplete multiresolution representations. We show that efficient representations may be identified from digital mammograms and used to enhance features of importance to mammography within a continuum of scale-space. We present a method of contrast enhancement based on an overcomplete, non-separable multiscale representation: the hexagonal wavelet transform. Mammograms are reconstructed from transform coefficients modified at one or more levels by local and global non-linear operators. Multiscale edges identified within distinct levels of transform space provide local support for enhancement. We demonstrate that features extracted from multiresolution representations can provide an adaptive mechanism for accomplishing local contrast enhancement. We suggest that multiscale detection and local enhancement of singularities may be effectively employed for the visualization of breast pathology without excessive noise amplification.</abstract>
    <subject>
        <topic>Biomedical engineering</topic>
    </subject>
    <relatedItem type="host">
        <titleInfo>
            <title>Medical imaging 1993 : Image processing : 16-19 February 1993, Newport Beach, California ; Proceedings of SPIE, vol. 1898</title>
        </titleInfo>
        <name type="personal">
            <namePart type="family">Loew</namePart>
            <namePart type="given">Murray H.</namePart>
            <role>
                <roleTerm type="text">editor</roleTerm>
            </role>
        </name>
        <originInfo>
            <place>
                <placeTerm type="text">Bellingham, Wash.</placeTerm>
            </place>
            <publisher>SPIE</publisher>
            <dateIssued encoding="w3cdtf">1993</dateIssued>
        </originInfo>
        <identifier type="doi">10.1117/12.154543</identifier>
    </relatedItem>
    <identifier type="hdl">http://hdl.handle.net/10022/AC:P:9582</identifier>
    
    <location>
        <physicalLocation authority="marcorg">NNC</physicalLocation>
    </location>
    <accessCondition type="use and reproduction">
        <copyrightNotice>Copyright 1993 Society of Photo-Optical Instrumentation Engineers. One print or electronic copy may be made for personal use only. Systematic electronic or print reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited.</copyrightNotice>
    </accessCondition>
    
    <recordInfo>
        <recordContentSource authority="marcorg">NNC</recordContentSource>
        <recordCreationDate encoding="w3cdtf">2010-08-30 10:07:47 -0400</recordCreationDate>
        <recordChangeDate encoding="w3cdtf">2011-09-02 13:39:00 -0400</recordChangeDate>
        <recordIdentifier>2147</recordIdentifier>
        <languageOfCataloging>
            <languageTerm authority="iso639-2b">eng</languageTerm>
        </languageOfCataloging>
    </recordInfo>
    
</mods>